ABSTRACT

SARS-CoV-2 has spread rapidly, causing deaths worldwide. In this study, we evaluated the performance of the BD MAX Open System module for identifying viral pathogens, including SARS-CoV-2, in nasopharyngeal specimens from individuals with symptoms of upper respiratory tract infection. We developed and validated a rapid total nucleic acid extraction method based on real-time reverse transcription-polymerase chain reaction (RT-PCR) for the reliable, high-throughput simultaneous detection of common cold viral pathogens using the BD MAX Platform. The system was evaluated using 205 nasopharyngeal swab clinical samples. For assessment of the limit of detection (LoD), we used SARS-CoV-2, influenza A/B, and respiratory syncytial virus (RSV) RNA standards. The BD MAX dual multiplex real-time RT-PCR panel demonstrated a sensitivity comparable to that of the World Health Organization-recommended SARS-CoV-2 assay with an LoD of 50 copies/PCR. The LoD of influenza A/B and RSV was 100-200 copies/PCR. The overall percent agreement between the BD MAX panel and laboratory-developed RT-PCR test on 55 SARS-CoV-2-positive clinical samples was 100%. Among the 55 positive cases of COVID-19 analysed, no coinfection was detected. The BD MAX rapid multiplex PCR provides a highly sensitive, robust, and accurate assay for the rapid detection of SARS-CoV-2, influenza A/B, and RSV.


Subject(s)
COVID-19/diagnosis , Influenza, Human/diagnosis , Polymerase Chain Reaction/methods , Respiratory Syncytial Virus Infections/diagnosis , SARS-CoV-2/genetics , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19 Testing , Coinfection/epidemiology , Female , Humans , Male , Middle Aged , Multiplex Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/methods , Reverse Transcriptase Polymerase Chain Reaction/methods , Young Adult
2.
Clin Chim Acta ; 514: 54-58, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-971428

ABSTRACT

BACKGROUND AND AIMS: Immediate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for preventing the spread of coronavirus disease 2019 (COVID-19). The LabTurbo AIO 48 system is an automated platform that allows nucleic acid extraction and sample analysis on the same instrument, producing faster results without affecting their accuracy. We aimed to independently evaluate the LabTurbo AIO 48 (all-in-one system) for SARS-CoV-2 detection. MATERIALS AND METHODS: Comparative limit of detection (LOD) was assessed on both the LabTurbo AIO 48 and current standard detection system based on real-time reverse transcriptase polymerase chain reaction (RT-PCR), using SARS-CoV-2 RNA control. Additional 125 primary clinical samples were assessed using both the protocols in parallel. RESULTS: The turnaround time from sample to results for 48 samples analyzed on LabTurbo AIO 48 was approximately 2.5 h, whereas that analyzed using the in-house RT-PCR protocol was 4.8 h. LabTurbo AIO 48 also demonstrated higher sensitivity than our reference RT-PCR assay, with a LOD of 9.4 copies/reaction. The overall percentage agreement between both the methods for 125 samples was 100%. CONCLUSION: LabTurbo AIO 48 is a robust detection option for SARS-CoV-2, allowing faster results and, consequently, aiding in better control and prevention of COVID-19.


Subject(s)
COVID-19 Testing/methods , High-Throughput Screening Assays/methods , Real-Time Polymerase Chain Reaction/methods , COVID-19/diagnosis , Humans , Limit of Detection , RNA, Viral/chemistry , Reference Standards , Sensitivity and Specificity , Viral Load
3.
PeerJ ; 8: e9318, 2020.
Article in English | MEDLINE | ID: covidwho-604693

ABSTRACT

Coronavirus disease 2019 has become a worldwide pandemic. By April 7, 2020, approximately 1,279,722 confirmed cases were reported worldwide including those in Asia, European Region, African Region and Region of the Americas. Rapid and accurate detection of Severe Acute Respiratory Syndrome Virus 2 (SARS-CoV-2) is critical for patient care and implementing public health measures to control the spread of infection. In this study, we developed and validated a rapid total nucleic acid extraction method based on real-time RT-PCR for reliable, high-throughput identification of SARS-CoV-2 using the BD MAX platform. For clinical validation, 300 throat swab and 100 sputum clinical samples were examined by both the BD MAX platform and in-house real-time RT-PCR methods, which showed 100% concordant results. This BD MAX protocol is fully automated and the turnaround time from sample to results is approximately 2.5 h for 24 samples compared to 4.8 h by in-house real-time RT-PCR. Our developed BD MAX RT-PCR assay can accurately identify SARS-CoV-2 infection and shorten the turnaround time to increase the effectiveness of control and prevention measures for this emerging infectious disease.